Nach der Anmeldung stehen Ihnen an einigen Stellen der Seite erweiterte Informationen zur Verfügung.

Publikationen von
Felix Wiesner

Alle Publikationen des HI Jena

2022

S. Fuchs, J. Abel, J. Nathanael, J. Reinhard, F. Wiesner, M. Wuensche, S. Skruszewicz, C. Roedel, D. Born, H. Schmidt, and G. Paulus
Photon counting of extreme ultraviolet high harmonics using a superconducting nanowire single-photon detector
Applied Physics B 128, 26 (2022)

Abstract: Laser-driven light sources in the extreme ultraviolet range (EUV) enable nanoscopic imaging with unique label-free elemental contrast. However, to fully exploit the unique properties of these new sources, novel detection schemes need to be developed. Here, we show in a proof-of-concept experiment that superconducting nanowire single-photon detectors (SNSPD) can be utilized to enable photon counting of a laser-driven EUV source based on high harmonic generation (HHG). These detectors are dark-count free and accommodate very high count rates-a perfect match for high repetition rate HHG sources. In addition to the advantages of SNSPDs for classical imaging applications with laser-driven EUV sources, the ability to count single photons paves the way for very promising applications in quantum optics and quantum imaging with high energetic radiation like, e.g., quantum ghost imaging with nanoscale resolution.

2021

S. Skruszewicz, S. Fuchs, J. J. Abel, J. Nathanael, J. Reinhard, C. Rödel, F. Wiesner, M. Wuensche, P. Wachulak, A. Bartnik, K. Janulewicz, H. Fiedorowicz, and G. G. Paulus
Coherence tomography with broad bandwidth extreme ultraviolet and soft X-ray radiation
Applied Physics B 127, 55 (2021)

Abstract: We present an overview of recent results on optical coherence tomography with the use of extreme ultraviolet and soft X-ray radiation (XCT). XCT is a cross-sectional imaging method that has emerged as a derivative of optical coherence tomography (OCT). In contrast to OCT, which typically uses near-infrared light, XCT utilizes broad bandwidth extreme ultraviolet (XUV) and soft X-ray (SXR) radiation (Fuchs et al in Sci Rep 6:20658, 2016). As in OCT, XCT\textquotesingle s axial resolution only scales with the coherence length of the light source. Thus, an axial resolution down to the nanometer range can be achieved. This is an improvement of up to three orders of magnitude in comparison to OCT. XCT measures the reflected spectrum in a common-path interferometric setup to retrieve the axial structure of nanometer-sized samples. The technique has been demonstrated with broad bandwidth XUV/SXR radiation from synchrotron facilities and recently with compact laboratory-based laser-driven sources. Axial resolutions down to 2.2 nm have been achieved experimentally. XCT has potential applications in three-dimensional imaging of silicon-based semiconductors, lithography masks, and layered structures like XUV mirrors and solar cells.

F. Wiesner, M. Wünsche, J. Reinhard, J. Abel, J. Nathanael, S. Skruszewicz, C. Rödel, S. Yulin, A. Gawlik, G. Schmidl, U. Huebner, J. Plentz, G. Paulus, and S. Fuchs
Material-specific imaging of nanolayers using extreme ultraviolet coherence tomography
Optica 8, 230 (2021)

Abstract: Scientific and technological progress depend substantially on the ability to image on the nanoscale. In order to investigate complex, functional, nanoscopic structures like, e.g., semiconductor devices, multilayer optics, or stacks of 2D materials, the imaging techniques not only have to provide images but should also provide quantitative information. We report the material-specific characterization of nanoscopic buried structures with extreme ultraviolet coherence tomography. The method is demonstrated at a laser-driven broadband extreme ultraviolet radiation source, based on high-harmonic generation. We show that, besides nanoscopic axial resolution, the spectral reflectivity of all layers in a sample can be obtained using algorithmic phase reconstruction. This provides localized, spectroscopic, material-specific information of the sample. The method can be applied in, e.g., semiconductor production, lithographic mask inspection, or quality control of multilayer fabrication. Moreover, it paves the way for the investigation of ultrafast nanoscopic effects at functional buried interfaces. Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License.

2020

S. Fuchs, F. Wiesner, M. Wünsche, J. Nathanael, J. Abel, J. Reinhard, C. Rodel, and G. Paulus
Quantitative nanoscale coherence tomography with extreme ultraviolet light
(2020)

Abstract: We present nanoscale coherence tomography (XCT) in the extreme ultraviolet range driven by a high-harmonic generation (HHG) light source. Using a novel phase retrieval algorithm, XCT enables non-destructive, quantitative, cross-sectional imaging, of, e.g., semiconductor devices.

2019

J. Nathanael, M. Wünsche, S. Fuchs, T. Weber, J. Abel, J. Reinhard, F. Wiesner, U. Hübner, S. Skruszewicz, G. Paulus, and C. Rödel
Laboratory setup for extreme ultraviolet coherence tomography driven by a high-harmonic source
Review of Scientific Instruments 90, 113702 (2019)

Abstract: We present a laboratory beamline dedicated to nanoscale subsurface imaging using extreme ultraviolet coherence tomography (XCT). In this setup, broad-bandwidth extreme ultraviolet (XUV) radiation is generated by a laser-driven high-harmonic source. The beamline is able to handle a spectral range of 30-130 eV and a beam divergence of 10 mrad (full width at half maximum). The XUV radiation is focused on the sample under investigation, and the broadband reflectivity is measured using an XUV spectrometer. For the given spectral window, the XCT beamline is particularly suited to investigate silicon-based nanostructured samples. Cross-sectional imaging of layered nanometer-scale samples can be routinely performed using the laboratory-scale XCT beamline. A depth resolution of 16 nm has been achieved using the spectral range of 36-98 eV which represents a 33% increase in resolution due to the broader spectral range compared to previous work.

M. Wünsche, S. Fuchs, T. Weber, J. Nathanael, J. Abel, J. Reinhard, F. Wiesner, U. Hübner, S. Skruszewicz, G. Paulus, and C. Rödel
A high resolution extreme ultraviolet spectrometer system optimized for harmonic spectroscopy and XUV beam analysis
Review of Scientific Instruments 90, 023108 (2019)

Abstract: We present a modular extreme ultraviolet (XUV) spectrometer system optimized for a broad spectral range of 12-41 nm (30-99 eV) with a high spectral resolution of lambda/Delta lambda greater than or similar to 784 +/- 89. The spectrometer system has several operation modes for (1) XUV beam inspection, (2) angular spectral analysis, and (3) imaging spectroscopy. These options allow for a versatile use in high harmonic spectroscopy and XUV beam analysis. The high performance of the spectrometer is demonstrated using a novel cross-sectional imaging method called XUV coherence tomography.

F. Wiesner, S. Fuchs, M. Wünsche, J. Nathanael, J. Abel, J. Reinhard, S. Skruszewicz, C. Rödel, A. Gawlik, G. Schmidl, and . others
Label-free quantitative material sensitive tomography with extreme ultraviolet light
(2019)

Abstract: We report on quantitative material-sensitive cross-sectional imaging with nanoscale axial resolution. First experimental results show that in addition to the structural information element-specific identification of buried layers is possible.

S. Fuchs, M. Wünsche, J. Nathanael, J. Abel, J. Reinhard, F. Wiesner, S. Skruszewicz, C. Rödel, and G. Paulus
XUV coherence tomography with nanoscale resolution using one-dimensional phase retrieval
(2019)

Abstract: We present XUV Coherence Tomography (XCT) driven by a high-harmonic generation (HHG) light source. Using a novel one-dimensional phase retrieval algorithm, XCT enables non-destructive, artifact-free, nanoscale, cross-sectional imaging, of, e.g., semiconductor devices.